Signal Report Date: Jan 12 2026
Rating of: CAE 2
Report of Signal 2 of Experiment 2: S1SENS020000FO0D
Overall Rating: 0.9141
Versuchskurven Vergleich Versuch-Berechnung

test_01
Average of experiments

test_02
cross-correlation reference

test_03
cae_02

test_04
Limits Outer corridor

Limits inner corridor
Method Name Rating Weight
1 Corridor Method 0.8720 0.50
2
Correlation Method
Value Rating Weight
Cross correlation function 0.9906 0.9540 0.50
Size 0.9166 0.9166 0.250
Phase shift 0.6 1.0 0.250
0.9562 0.50
3 Combination of 1 and 2 0.9141 -
Parameters: Evaluation Intervall: 9.9 - 169.9
Method 1: Max. half width of inner corridor: 0.050
Max. half width of outer corridor: 0.50
Corridor curve file:
Reference value: 3203.9291
Transition exponent: 2
Method 2: Limits for phase shift: 1.6 - 19.2
Rating exponents (shape, size, phase): 10, 1, 1